TLB50 115V-60Hz

TLB50 is a thawing bath for sample preparation. The bath has an operating range of -5°C up to +80°C. The benchtop bath with integrated cooling can replace the combination of a water bath with an external cooling circulator. This not only saves bench space, but also costs because of its high cooling efficiency. The TLB50 has a wide bath opening and several options like a fixed or split levelling platform and adjustable rack for placing different sized sample bottles. The primary use of the TLB50 is sample conditioning. Before most samples are analysed, they require to be conditioned to a specified temperature as described in each test method
SKU
00T0071
€5,257.00
More Information
Bath Temperature Accuracy 0.02°C
Bath Volume 50 litre
Bath Height 720 mm
Weight 65.0000
Specification click here
Manual click here
Minimum Temperature -5°C
Maximum Temperature 80°C
TLB50 is a thawing bath for sample preparation. The bath has an operating range of -5°C up to +80°C. The benchtop bath with integrated cooling can replace the combination of a water bath with an external cooling circulator. This not only saves bench space, but also costs because of its high cooling efficiency. The TLB50 has a wide bath opening and several options like a fixed or split levelling platform and adjustable rack for placing different sized sample bottles. The primary use of the TLB50 is sample conditioning. Before most samples are analysed, they require to be conditioned to a specified temperature as described in each test method. Examples are: - ASTM D323 Reid vapour pressure test between 0 to 1°C (32 to 34°F).- ASTM D5 Penetration tests for bitumen. - Long-term storage of gasoline <10°C or <20°C (<50° to 68°F).- ASTM D86 Distillation.
The used cooling system is ozone friendly and doesn’t contain any CFK/HCFK gas.
The fluid temperature is regulated through an electronic controlled heater and leaving the cooling compressor running continuously. The cooling power is maximized for rapid cooling down of the bath. When the set point temperature is reached cooling power is strongly reduced and it is saving significant energy. In comparison to other standard instruments the TLB50 can save up to 600 Watt of electric energy. Above 40°C cooling is switched-off automatically to save energy.
The temperature readout readout is in two decimals and can be switched between °C or °F via the menu.
The bath with stirrer (P/N 00T0071, 00T0072 and 00T0073) uses a vain to stir the bath liquid. A special baffle plate ensures maximum homogeneity. TLB50 with pump (P/N 00T0071, 00T0072, 00T0073) provides circulation in the bath or via an external circuit. The pump offers 7 litres per minute. Maximum pressure is 300 mBar. Connector ¼” or 80 mm hose.